Skip to content
Reynaers - REY.B.005-006

Reynaers Aluminium NV

Reynaers - REY.B.005-006

Category: Glazed Facades

Add to shortlist

Description

Mullion to transom connection is comparable to the CW 50-EP façade system, manufactured by Reynaers
This detail shown is a CPNI recommended modification of a standard CW 50-EP connection detail and is one of the 5 measures that should be incorporated into the design of the stick curtain walling system, to achieve the mitigation protection level detailed in CPNI Guidance Note: Blast Mitigation Measures for Stick Curtain Wall Systems.

  

Connection details: 
Reynaers CW 50-EP Transom-Mullion

Drawing number:
REY.B.005-006

Compatible frame system:
Reynaers CW 50-EP

The CPNI stick curtain wall system mitigation measures focus on five key elements of the façade design. All five of the recommended key elements must be implemented to achieve the hazard reduction.

The five key elements are:

  1. Connection between the façade and the structure
  2. Façade frame 
  3. Transom to mullion connection
  4. Glazing 
  5. Glass retention